Cold air from the vents is the most common winter heating call in Albuquerque. Work through these in order.
1. Thermostat set to fan ON
If the fan is set to ON instead of AUTO, it blows air even when the burners are off. Switch it to AUTO.
2. Dirty filter tripping the limit switch
A clogged filter makes the furnace overheat, so a safety switch shuts the burners off while the fan keeps running. Replace the filter and give it 15 minutes.
3. Failed igniter
Hot-surface igniters crack with age. If you hear the inducer motor start but the burners never light, the igniter is a prime suspect.
4. Dirty flame sensor
Burners light for a few seconds and then shut off. A technician cleans or replaces the sensor.
5. Pilot light out
Older furnaces and wall heaters use a standing pilot. If it will not stay lit, the thermocouple is often worn.
6. Condensate problem (high-efficiency furnaces)
A clogged drain or frozen line can shut a 90%+ furnace down. Look for water or an error code.
7. Gas supply
Check that other gas appliances work and the furnace gas valve is open. If you smell gas, leave and call New Mexico Gas Company at 888-664-2726.
When to call
If the filter and thermostat are fine and it still blows cold, call. Igniter, flame sensor and control problems are quick fixes for a technician.
Helpful links: New Mexico Gas Company rebates · PNM energy efficiency programs · CPSC: carbon monoxide safety